Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-108
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
53BHE00
RC4 EEPROM data verify
error during Deposit End.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
53BHF00
RC5 EEPROM data verify
error during Deposit End.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
53BHG00
NO detectiong nter Lock in the
RC EEPROM R/W during
Deposit End.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
53BR000
RBU response timeout during
Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
53BR700
RBU response message
timeout error during Deposit
End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
53BS000
RBU communication timeout
error during Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
53BS100
RBU connection sequence
error during Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
53BS200
RBU connection MI error
during Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
53US100
USB Sequence duplicated
number error during Deposit
End.
1. Restart over AP-SP
53US300
USB command data length
error during Deposit End.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5400100
GS801 light jam error during
Deposit Cancel .
1. Open the upper unit.
2. Open the customer service module
(CSM)
3. Open the BC(5)
4.Remove notes and substance in the
Front Transport Path(4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5400200
GS002 light jam error during
Deposit Cancel .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Rotate the knob of the Front
Transport Path(4)
5. Remove the Jam between BC(5) and
Front Transport Path(4).