Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-471
Code
Problem Description
Troubleshooting
5K52200
Error occurred by the notes
remained on the GS502 during
Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K52500
Error occurred by the notes
remained on the (GS505)
during Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K55500
Error occurred by the
Transport Path(GS505) during
Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K56500
Error occurred by the Return
Transport Path(GS505) during
Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K57500
Error occurred by the notes
disorder on the GS505 during
Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance