Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-499
Code
Problem Description
Troubleshooting
5Q3GB00
Encoder Sensor(GS307) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS307 works fine if
there is nothing jammed.
5Q3GC00
Encoder Sensor(GS307) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS307 works fine if
there is nothing jammed.
5Q3GG00
Encoder Sensor(GS313) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction.
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS313 works fine if
there is nothing jammed.
5Q3GH00
Encoder Sensor(GS313) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS313 works fine if
there is nothing jammed.
5Q3J300
RC3 full check failure during
Retract CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Check the stage status after open the
recycle cassette(C)
5. Check contamination status of the
GS312 sensor.
5Q3R100
RC3 message timeout error
during operation ready in the
Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q3R300
RC3 message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q3S100
Undefined return value of RC3
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
5Q3S200
Undefined command of RC3
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)