background image

CCV

IM30

User Manual 
Rev.04

www.ccv.eu/im30

Summary of Contents for 03385-55

Page 1: ...CCV IM30 User Manual Rev 04 www ccv eu im30 ...

Page 2: ...or 08 4 5 SAM SIM 09 4 6 Buttons 09 4 7 MDB status LED 09 5 Installation 10 6 Connectors 11 6 1 Power Digital IO 11 6 2 RS232 A cash register 11 6 3 RS232 B COM 12 6 4 Ethernet 13 6 5 MDB Slave 13 6 6 MDB Master Executive 14 6 7 USB 15 6 8 AUX 16 7 Startup 17 8 Labels and seals 18 9 FCC Compliance Statement 19 10 CE Declaration of Conformity 20 11 Datasheet 20 Table of Content ...

Page 3: ...umed for any damage that occurs No liabilitywill be accepted for damage or injury resulting from incorrect operation or from failure to observe the safety guidelines Integration of the product may only be carried out of qualified by electrical specialists i e electrician according to the relevant regulations i e VDE CE If you have no specialist knowledge regarding the installation do not carry thi...

Page 4: ...al use its surface should still be keep clear of dirt and possible liquid contamiants While the terminal is designed to resist ingress of dust and liquids such as water hoses Keep the back of the device away from dust and liquids as much as possible Maintain a sufficient distance to other electrical devices this can lead to malfunctions Make sure the various cables connect to provide the appropria...

Page 5: ...le for malfunctions or damage caused by lack of maintenance updates or maintenance errors due to the customer CCVsupportsyouduringtheinitialinstallationoftheproductintovending orothermachine andrecommends a joint check of your vendingmachine terminal integration on site prior to piloting so that typical problems can be eliminated in advance Please contact you reseller or CCV directly for details o...

Page 6: ...iption 4 1 Front view LCD touchscreen contacless card interface code scanning camera front facing camera camera locator light magnetic stripe card reader status LED and proximity sensor smart card reader 1 2 3 4 5 6 7 ...

Page 7: ...l devices USB type A port host headphone jack mic speaker USB type C port OTG LAN port 10 100 Mbit download button digital I O power 6pin WAGO connector reset button executive MDB Master port HDMI port 4G antenna MDB Slave port 1 2 3 4 5 6 7 15 9 10 11 12 13 14 SAM card module 8 ...

Page 8: ...a RGB status indicator LED obove the proximity detector The operation of the LED is software controlled It can display a light in red green or blue The CCV IM30 has a optical proximity detector located near the lower right side of of its front face The proximity sensor detects light in the visible spectrum and can be tuned to detect objects at a user configurable distance It is meant to perform fu...

Page 9: ...the SIM card with the clipped corner facing inwards and to the left 4 6 Buttons The terminal does have two buttons on the back One for service and one to reset the terminal 4 7 MDB status LED The terminal does have a MDB status LED on the back which shows status in active state green Idle state ready to use Out of order red Make your choice and or present your card for payment or revalue yellow fl...

Page 10: ...those of a standard door module as defined by the European Vending Association The M4 stud bolds should extrude from the back of the mounting plate to allow for the mounting bracket to slot into place 5 Installation Attention Mounting the 4xM4 screws has to be done with a moment of force about 1 2Nm 0 2Nm ...

Page 11: ...nector also enables a digital IO port 1 DIGI_IN3 DIGI_IN2 2 DIGI_IN1 3 PWR DIG I O WAGO 6pin PIN DIGI_OUT1 4 5 GND MDB_PWR_OUT 6 6 2 RS232 A cash register RJ45 8 poles high speed interface default 115 2 kbps switchable up to 921 6 kbps shielded hardware handshake max cable length 100 cm 1 POWER_IN RX 2 TX 3 Signal PIN ...

Page 12: ...nterface default 115 2 kbps switchable up to 921 6 kbps shielded hardware handshake max cable length 100 cm software con trolled supply voltage output to also supply external components besides communication 1 POWER_OUT RX 2 TX 3 Signal PIN MDB_WAKEUP 4 5 RTS CTS 6 7 GND GND 8 ...

Page 13: ...ultidrop Bus MDB is a communication protocoll commonly used in vending machines The CCV IM30 has a MDB slave port that can communicate to a vending machine controller as well as accept an input voltage of 9V to 42V MDB Master and MDB Slave to provide two separated MDB connectors with two sepa rated communcation ports MDB level 1 2 and 3 are supported 1 VDC GND 2 NC 3 Signal PIN RX 6 NC 8 ...

Page 14: ...endinging machines The CCV IM30 has a custom 20 pin connector Amphenol 69168 that functions as a MDB master port as well an Executive port 1 MDB_PWR_IN GND 2 V_OUT unswitched 3 Signal PIN 5 MDB_MASTER_RX MDB_MASTER_TX 6 GND 4 7 GND GND 8 EXE_MASTER_RX 9 11 GND GND 12 EXE_MASTER_TX 10 13 DIGI_IN4_H DIGI_OUT2_H 14 DIGI_IN4_L 15 17 MDB_WAKEUP DIGI_OUT2_L 16 ...

Page 15: ...SB Host port available for use it can accept 5V input to power the device 1 VIN D 2 D 3 Signal PIN GND 4 USB Host type A USB OTG type C B1 GND A1 GND A2 NC B2 NC A3 NC B3 NC Signal Signal A4 VBUS B4 VBUS B5 USB_ID A5 USB_ID A6 D B6 D A7 D B7 D USB Host type A USB OTG type C ...

Page 16: ...uxiliary jack is a term for a variety of analog port usually made to transfer audio data The CCV IM30 has a 3 5 mm auxiliary jack that can output a stereo audio signal and accept the input of a microphone 7 MIC GND 2 AUDIO_LEFT 3 Signal PIN AUDIO_FEEDBACK 4 5 AUDIO_DETECT AUDIO_RIGHT 6 ...

Page 17: ...art startup sequence use application menu password 3333 Android OS password is pax9876 8 entercash registerport1 7 confirm withOK 6 selectSSL connection 10 entercash reg port2 9 confirm withOK 12 select communication target PU 11 confirm withOK 14 receive terminalID 13 confirm withOK 15 diagnosis withhost ...

Page 18: ...17 startup finished 16 EMVdiagnosis withhost 18 terminal readyfor operation 8 Labels and seals ...

Page 19: ...ed by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for he...

Page 20: ... 11 Datasheet LAN Bluetooth WiFi RFModem Product 03385 55 03397 55 CCV IM30 Configuration Options Part Number Power supply SupplyVoltage 7 48 V DC via main power connector 7 V 48 V DC via MDB Slave 7V 48 V DC via RS232 19V 30 V AC via Executive and optional MEI cable Full Operation 650 mA peakwithout active 4G modem Power Save Mode typ 6mA in without active 4G modem Max power 700mA 12V Full Operat...

Page 21: ...0MBit RJ45 WLAN 2 4 5GHz WiFi integrated 4G integrated global roaming capable Optional 4G modem field integration ready RFModem MDB MDB Slave MDB Master via 20pin Telemetry connector Executive Executive Master via 20pin Telemetry connector MEI and BDV compliant Video 1x HDMI Audio integrated loudspeaker 1x AUX 3 5mm TRRS audio jack for loudspeaker and microphone Digital I OS 1x Output switched GND...

Page 22: ...O 7813 Bluetooth Integrated BLE 5 0 QR Scanner 0 3 MP Reads 1D 2D codes LED illuminated Camera 2 0 MP Environmental Conditions Certifications 20 to 70 C 4 F 158 F Operating Temperature Range Storage Temperature Range 30 to 70 C 22 F 158 F Operating Humidity Range 5 95 RH non condensing Shock IK08 Vibration Compliant to IEC 60068 2 6 Ingress Protection Class IP 55 Flammability rating V2 according t...

Page 23: ... only HID iClass serial number only Front Plane Cut Out W x H x D mm 105 x 146 x 31 5 at machine front W x H x D mm 82 2 x 107 2 x 25 2 within machine 481 g 5 including 4G RF modem without cables and mounting material 454 g 5 without cables and mounting material Only available until all certifications have been granted All power consumption values based on 12V DC supply serial number only full tec...

Reviews: