Code
Problem Description
Troubleshooting
578HF17
Error to load recognition DB
#07 during Withdrawal.
1.Download DB again after delecting all
recognition DB
2. Operate to initialize BRM(Recovery)
578HF18
Error to load recognition DB
#08 during Withdrawal.
1.Download DB again after delecting all
recognition DB
2. Operate to initialize BRM(Recovery)
578HF19
Error to load recognition DB
#09 during Withdrawal.
1.Download DB again after delecting all
recognition DB
2. Operate to initialize BRM(Recovery)
578HF20
Error to load recognition DB
#10 during Withdrawal.
1.Download DB again after delecting all
recognition DB
2. Operate to initialize BRM(Recovery)
578HG01
Error of mode set up during
BCU Mode Command in the
Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
578HG02
Error of the recognition level
set up during BCU mode
command in the Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
578HG03
Error of the transaction ready
set up during BCU ready
command in the Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
578HG04
Error of mode set up during
BCU ready command in the
Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
578HG05
Error of the recognition level
set up during BCU ready
command in the Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
578HG06
Error of the BC insert direction
during BCU ready command
in the Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
578HG07
Error of BCU undefined
command reception during
Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
578HG08
Error of available support
country numbers set up during
receiving BCU data write
command in the Withdrawal .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
578HG09
Error of country-code set up
during receiving BCU data
write command in the
Withdrawal .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
578HG10
Error of no recognition DB for
the country during receiving
BCU data write command in
the Withdrawal .
1. Check the country
2. Download DB again after delecting all
recognition DB
3. Operate to initialize BRM(Recovery)
4. Reboot the system when same error
occurred after initialization
578HG11
Error of no country code set up
during receiving BCU ready
command in the Withdrawal .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
578HG12
BC spec differs from data write
command paramter during
Withdrawal .
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio