Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-98
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
538HG03
Error of the transaction ready
set up during BCU ready
command in the Deposit
End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
538HG04
Error of mode set up during
BCU ready command in the
Deposit End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
538HG05
Error of the recognition level
set up during BCU ready
command in the Deposit
End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
538HG06
Error of the BC insert direction
during BCU ready command
in the Deposit End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
538HG07
Error of BCU undefined
command reception during
Deposit End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
538HG08
Error of available support
country numbers set up during
receiving BCU data write
command in the Deposit
End .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
538HG09
Error of country-code set up
during receiving BCU data
write command in the Deposit
End .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
538HG10
Error of no recognition DB for
the country during receiving
BCU data write command in
the Deposit End .
1. Check the country
2. Download DB again after delecting all
recognition DB
3. Operate to initialize BRM(Recovery)
4. Reboot the system when same error
occurred after initialization
538HG11
Error of no country code set up
during receiving BCU ready
command in the Deposit
End .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
538HG12
BC spec differs from data write
command paramter during
Deposit End .
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio
538HG20
Error to initialize CIS during
receiving BCU ready command
in the Deposit End .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
538HG21
Error of power on during
receiving BCU ready command
in the Deposit End .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance