Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-432
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5F6G100
Error of BP stack position
movement during Shutter
Close.
1. Open the upper Unit.
2. Open the customer service
module(CSM) shutter(1).
3. Check the notes and substance
inside of the CSM.
5F6G200
BP deposit position movement
error during Shutter Close.
1. Open the upper unit.
2. Open the customer service module
(CSM) Shutter(1).
3. Check the notes and substance
inside of the CSM.
5F6GD00
Failure to Lift-up during Shutter
Close.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
5F6GE00
Failure to Lift-down during
Shutter Close.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
5F6GF00
Failure to move gate roller to
home position during Shutter
Close.
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(2)
5F6M100
Stopper Init error during
Shutter Close.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5F6M300
Shutter Close error during
Shutter Close.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
5F6R100
CSM message timeout error
during operation ready in the
Shutter Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5F6R200
CSM message timeout error
during transaction operation in
the Shutter Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5F6R300
CSM message timeout error
during postprocessing of
Shutter Close.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5FAA200
Status of TE open before the
operation during Shutter Close.
1. Open the upper Unit
2. Check open/close of TE(12)
5FAA300
Status of BMU inter lock
detachment before Shutter
Close.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
5FAA400
Status of BMU removal before
Shutter Close.
1. Check Load/Removal of the upper
unit
5FAA600
Status of CSM open before the
operation during Shutter Close.
1. Open the upper Unit
2. Check open/close of CSM
3. Check sensor GS011