manualshive.com logo in svg
background image

Operating instruction

VENUS 6600 XL

Chip card system

Содержание VENUS 6600 XL

Страница 1: ...Operating instruction VENUS 6600 XL Chip card system ...

Страница 2: ...or safe and proper use read the instructions for use and further product related documents carefully and keep it for later use For errors technical errors printing errors and incompleteness we assume no liability ...

Страница 3: ...ereby confirmed that the construction in that execution brought by us in traffic corresponds to the standards specified down Diese Erklärung gilt für alle Geräte die nach den beiliegenden technischen Unterlagen welche Bestandteile dieser Erklärung sind hergestellt werden This explanation applies to all devices after the enclosed technical documents which are components of this explanation are manu...

Страница 4: ...1 2 2 Clock menu 17 11 2 3 Configuration menu 18 11 2 4 Bus configuration menu 20 12 Chip card revalue 21 12 1 Personnel revalue mode 21 13 Statistics 22 13 1 Explaining the statistics values 22 13 2 Enquiring the statistic values 22 13 3 Cancelling the statistic values 23 13 5 Enquiring the failure statistics 24 13 6 Readout the code 24 14 Not programmable special equipments 25 14 1 Electric cont...

Страница 5: ...ase note all the abbrevi ations appearing on the display definitely for any other technical requests in the following list 2 Warranty On the function of the device is granted for a period of 12 months The warranty is limited solely to technical defects of the unit it can t be accepted further claims Further apply our general terms and conditions stand of June 2011 for products and services of the ...

Страница 6: ... and orders these details will constitute an advantage Please note all the abbreviations appearing on the display definitely for any other technical requests in the follo wing list Casing material galvanised steel plate 2 mm Casing color powder coated white RAL 9016 Dimensions h 255 mm x w 120 mm x d 135 mm Power supply 230 V or 24 V 50 60 Hz Switched power 6 3 A by cos phi 1 Power absorption 10 V...

Страница 7: ...ENUS 6600XL techn Stand 04 2016 4074_04 2016 V09 2019 7 1 Casing 2 Frontplate with foil keyboard 3 Lock 4 LCD display 5 RESET PLUS OK button 6 Short manual 7 Card slot 1 2 3 4 5 6 7 7 Illustrations 7 1 Illustration of device ...

Страница 8: ... relay 6b Fuse lead relay 7 Power connection 8 Connection for potential free relay 9 PCB fuse 10 Connection for foil keyboard 11 Connection for chip card contact unit 12 Connection for chip card reject 13 Connection for external timer 14 DIP switch no 1 4 15 Connection for remote start 16 Connection for time hold cleaning button Special equipment PCB XL2_V021 230V Jp FS 0 Jp FS standard Jumper rem...

Страница 9: ...can only be 2 now mark the drilled holes Drill the holes and insert suitable dowels Make the electrical connection through the holes in the bottom of the housing Then fix the housing with suitable screws Now restore the electrical connections to the front panel Fit the front panel and lock with the lock 8 Installation 8 1 Installation notes Through high quality micro electronics is the device able...

Страница 10: ...gulations With a permanent connection an all pole mains se parator with at least 3 mm contact gap must be used Before star ting the electric the corresponding circuit must be disconnected Shut down the mains input by activating the separator switch remove the fuse or release the main safety fuse Mains and low voltage cable must be spaced apart Low voltage cables should be generally spaced as scree...

Страница 11: ... main time is appropriated to the sun bed Do not choose the main time too long because of the danger of the sun bed customer Use the adjustment setting to limit the maximum time and therefore limi ting the maximum account of buyable main time to reduce to a minimum the danger to the customer 8 5 1 LED operating light With the LED operating light one can see at a glance the ope rating stand of the ...

Страница 12: ...p card amount Minimum debit Happy Hour discount Skin type indentification UV Control tanning management Electronic operating hours counter Electronic service hours counter Electronic customers counter electronic revaluation and devaluation counter Electric contactor Time stop cleaning button delete button Remote control Remote start Potential free relay contact LED display Design foil Chip card se...

Страница 13: ...ker you need to keep pushing the OK button If the OK button is kept pushed the menu is flowing forward Besi de this you can also access the menu backward short push on the OK button min 300ms max 850 ms If you have pushed shortly the OK button the auto repeat menu is accessed back wards By short pushing of the ok button you can access the menu again forward 11 1 Explanation of the program position...

Страница 14: ...ice It can be adjusted in steps of 5 seconds to a max of 9 min 55 sec The pre run count down can be pre maturely interrupted by the remote start Remote start The remote start gives the possibility to activate by an external button 2 pro cedures are possible In the first case the pre run time is set on lower than 0 In this case the pre run time was ended by pressing the remote start and the main ti...

Страница 15: ...ram the amount payable for each main time It is adjustable from 0 1 EUR SFr up to 99 9 EUR SFr in 0 1 10 or 100 steps depending on the digits after comma The full price must be paid to buy each main time Price step card 1 0 EUR The price step card offers the possibility to use the following described func tions by activated minimum payment By the first press of the PLUS key the full card price is ...

Страница 16: ...ill show the time in minutes HQL time yes The HQL Time offers the possibility to hinder the new start of a main time during the run out time The newly bought main time will be accounted with the amount of remaining run out time of the payment If this function is not activated then the run out time is immaterial the main time will start as soon as the pre run time has ended Should the compulsory re...

Страница 17: ...f October it will be automatic set on wintertime The changing timings will be calculated and do not have to be set At the beginning of the summer time the clock will be set up with 1 hour forward at night from 2 00 to 3 00 at the end of the season the clock will be set up 1 hour backward at night from 3 00 to 2 00 These timings are in agreement with the European Union summer time procedure They ha...

Страница 18: ...is freely chosen between tariff 1 2 3 and blockage A payment is not possible during the activated blockage Switch time Sa 1 First switching time valid only for Saturday Tariff Sa 1 First tariff valid only for Saturday The tariff is freely chosen between tariff 1 2 3 and blockage A payment is not possible during the activated blockage etc Also for Saturdays there are 4 time switches and 4 tariffs p...

Страница 19: ...f no is set the function is deactivated Daily counters yes The settings of Daily counters allows you to show or hide all daily counters in the statistics menu If yes is set all available daily counters are displayed If set to no no daily counters will be displayed 3 digits main time no The 3 digits main time offers the possibility to show the main time in 2 or 3 digits on the display If no is set ...

Страница 20: ...ess Every XL device must have a different device no There may not be distri buted double because the bus system can t read the particular address Besides the no of the SkinControl device must correspond with the no of the particular tanning beds Card Verify no This setting must generally be on no Testing no With the setting testing you have the possibility with the setting no not to show several e...

Страница 21: ...nt revalued which was previously determined in the price time menu in the menu item Revalue step card By pressing the RESET button these amounts can also be debited again in the same steps To completely erase the value of a chip card the PLUS and RESET buttons must be pressed simulta neously Confirm the process with OK As confirma tion the display shows Card value 0 0 EUR The display shows thereaf...

Страница 22: ...ill be made by RESET and PLUS button If both buttons are pressed at once the counter will be cancelled Service hours counter 1 The service hours counter is a operating hours counter however it can only count up to maximum of 999 hours This counter has with the service interval in time price menu an extra function There can be entered a number of hours in service interval 1 When the counter reaches...

Страница 23: ... To leave the menu remove the chip card The total operating hours counter can be pre set to a starting value by the RESET and PLUS button If both buttons are pushed at once the starting value will be cancelled Insert chip card type 43 Delete of the counts is pos sible daily counter only Insert chip card type 33 Delete of the totally counts is not possible daily counter only or Statistic menu to ca...

Страница 24: ...e statistics After advertisement of the error messages go along with OK button The code is advertised The acceptation of the H numbers are divided as follows H1 number of trader H2 number of customer H3 number of end customer H4 H5 are not assigned 255 Please note the first three H numbers ahead in your opera ting instruction for potential questions resp for new order of chip cards or new devices ...

Страница 25: ...2 pole screw terminal to connect an external button potential free closing contacts This special equipment can t be ordered together with the special equipment time stop or an external short impulse for the washing machine door 14 5 Internal short time impulse for washing machine door opening The short time impulse for the washing machine door opening offers the possibility using the RESET key or ...

Страница 26: ...art but ton If your VENUS has been ordered with a remote start button you can find on the SB frame on the inside of the back of the device an additional circuit board which needs to be connected to the remote indication as following The needed connection cable is not included by delivery Connection to the XL with 4 pol installation cable shielded screen on one side presented maximum conduit length...

Страница 27: ...E03 or E04 EEPROM memory is defect send VENUS to repair The display shows error message E06 DIP switch no 3 is on OFF set DIP switch no 3 on ON The display shows error message E12 Maximum time is adjusted smaller than the main time Adjust the maximum time or change the main time The display shows error message E14 The deletion is with this type of card not possible use chip card type 43 The displa...

Страница 28: ...Holtkamp Electronics VENUS 6600XL techn Stand 04 2016 4074_04 2016 V09 2019 28 ...

Страница 29: ...al at programming 13 General details 6 H Hours Minutes 16 HQL time 16 I Illustration of device 7 Illustration of electronic 8 Installation notes 9 Int door opener 19 Internal short time impulse 25 L Language 19 LED operating light 11 Legal information 5 M Main failure fuse 19 Main time 14 15 Malfunctions 27 Maximum time 15 Memory lock 19 Montageanleitung 9 Mounting notes 9 O Operating the first ti...

Страница 30: ...Holtkamp Electronics VENUS 6600XL techn Stand 04 2016 4074_04 2016 V09 2019 30 ...

Страница 31: ...Holtkamp Electronics VENUS 6600XL techn Stand 04 2016 4074_04 2016 V09 2019 31 ...

Страница 32: ...de Technical Stand 09 2019 We reserve the right to technical changes in the production and technical developments For technical information during our business hours Monday Thursday 8 00 a m 16 00 p m and Friday 8 00 a m 13 00 p m choose 49 541 97120 0 or visit our homepage www holtkamp de ...

Отзывы: