Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-257
Code
Problem Description
Troubleshooting
591G600
Exceeds retry count limit of
detecting RC1 stack
roller´s falling back and
avoiding during Customer
Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
591G700
Failure to move RC1 feed
roller to home position during
Customer Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
591G800
Failure to RC1 push pressure
movement during Customer
Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the upper side of the recycle
cassette
591GA00
RC1 solenoid echo disorder
error during Customer Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette(A) and
reload
4. Replace the cassette when same
error occurs
591GB00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Customer Change.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
591GC00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Customer Change.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
591GD00
Detect GS101, GS102 as
excessive notes during
Customer Change
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove note.
591GE00
Detect GS108(separate
pressure) as excessive note at
FM homeposition movement
durting Customer Change
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove note.