Error Code List Chapter4. Cash & Check In Module
4-28
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I18A9
[Initialize]Failure to check Motor
Fuse in CCIM main
board(NCM02)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18AA
[Initialize]Failure to check Motor
Fuse in CCIM main
board(CCM01)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18AB
[Initialize]Failure to check Motor
Fuse in CCIM main
board(CCM02)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18AC
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM06)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18AD
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM07)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18AE
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM10)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18AF
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM12)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18B0
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM13)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18B1
[Initialize]Failure to check Motor
Fuse in CCIM main
board(RCM01)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18B2
[Initialize]Failure to check Motor
Fuse in CCIM main
board(PRM01)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18B3
[Initialize]Failure to check Motor
Fuse in CCIM main
board(BDM01)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18B4
[Initialize]Failure to check Motor
Fuse in CCIM main
board(BDM06)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18E0
[Initialize] Anomaly of check
information
1. Remove the residual media in the
device.
2. Execute initialization.
I18F1
[Initialize]Internal Error while the
main task is operating.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I18FF
[Initialize] Failed to move to 3-Way
1 or 3-Way 2 Gate position
1. Open the BM2(7) and BM2(12) and
remove the residual media at the moving
path (7, 8, 9, 10).
2. Execute initialization.
I1901
[Initialize] A undefined position
has been entered.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I1902
[Initialize]Timeout occurs when
moving to the initial position for
initialization (PRS02 Dark) and the
limit of retries (3 times) is
exceeded.
1. Open the BM3 moving path and
remove the media.
2. If the same fault continuously occur
after checking the device, replace the
PRT Module.