Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-149
Code
Problem Description
Troubleshooting
I5C05
[Deposit Reject]JFDS05 Light
Timeout(88ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor and the Bundle.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I5C06
[Deposit Reject]JFDS03, 04 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM Separation and Send Check
(FDS01) sensor.
3. If no alien material exists in the SCM
Separation and Send Check (FDS01)
sensor,
Check whether the sensor is polluted.
I5C07
[Deposit Reject]JBCS01 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I5C08
[Deposit Reject]JBCS02 Light
Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I5C09
[Deposit Reject]JBCS01,BCS02
Light Timeout(500ms) fault when
separating media.
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM and the Bundle.
3. Check the SCM Half Lock state.
4. If no alien material exists in the SCM,
check whether the SCM internal media
detection sensors (FDS01, FDS02,
FDS03, FDS04, FDS05) are polluted.
I5C0A
[Deposit Reject]JFDS15 Light
Timeout fault
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I5C0B
[Deposit Reject]JAAS06 is not
reached (Light JAM) fault when
separating media.
1. BC(3) and SCM(2) Open
2. Remove the notes and alien materials
in the BC, SCM. and Bundle.
3. Check the BC and SCM Half Lock
state.
4. If no alien material exists in the BC
and SCM, check whether the SCM
internal media detection sensors
(FDS01, FDS02, FDS03, FDS04,
FDS05) are polluted.