Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-528
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5TAEE00
RBU RS485 communication
sequence disorder during
Module Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5TAEF00
RBU RS485 connection line
disorder during Module Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5TAH500
Error to
NVRAM(128denominations)
Read, Write during Module
Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization.
5TAR600
No response from task
message timeout error when
Module Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5TAR700
RBU response message
timeout error during Module
Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5TBHB00
RC1 EEPROM data verify
error when Module Test.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5TBHC00
RC2 EEPROM data verify
error when Module Test.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5TBHD00
RC3 EEPROM data verify
error when Module Test.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5TBHE00
RC4 EEPROM data verify
error when Module Test.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5TBHF00
RC5 EEPROM data verify
error when Module Test.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5TBHG00
No detect inter lock when RC
EEPROM R/W during Module
Test.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5TBS000
RBU communication timeout
error when Module Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5TBS100
RBU connection sequence
error when Module Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5TBS200
RBU connection MI error when
Module Test.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5TSSE00
Sequence number duplicated
with extra function command.
1. Check the detail sequence number of
bulk sending command
5TUS100
USB sequence number
duplicate error when Module
Test.
1. Restart over AP-SP