Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-117
Code
Problem Description
Troubleshooting
I4883
[Deposit Count/Check]The
maximum number of separables
at the Bundle part is exceeded
(subnormal).
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4884
Continous Reject error
(subnormal)
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4885
[Deposit Count/Check]A customer
gets notes before retracting those
(subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I4886
[Deposit Count/Check]A customer
gets notes while retracting those
(subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I4887
[Deposit Count/Check]A customer
gets notes before retracting those
(subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I4888
[Deposit Count/Check]A customer
gets notes while retracting those
(subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I4893
[Deposit Count/Check]Failure to
check the last note at the
termination of mid transport path
while retracting those .
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I48B4
[Initialize]Failure to check Motor
Fuse in CCIM main
board(BDM06)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I48E0
[Deposit Count/Check]Anomaly of
check information
1. Remove the residual media in the
device.
2. Execute initialization.
I48F1
[Deposit Count/Check]Internal
error while the main task is
operating.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I48FF
[Deposit Count/Check] Failed to
move to 3-Way 1 or 3-Way 2 Gate
position
1. Open the BM2(7) and BM2(12) and
remove the residual media at the moving
path (7, 8, 9, 10).
2. Execute initialization.