Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-69
Code
Problem Description
Troubleshooting
I330D
[Entry In/Out]Media remain in
Bundle when inhaling the media
(inducing discharge).
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle(1).
3. If no alien material exists, check
whether the sensor in the Bundle(1) is
polluted.
I330E
[Entry In/Out]Media do not remain
in Bundle when inhaling the media
(inducing re-inhale).
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle(1).
3. If no alien material exists, check
whether the sensor in the Bundle(1) is
polluted.
I330F
[Entry In/Out] Sensor fault when
preparing for separation of media.
1. Check the inside of the Bundle(1).
2. Remove the notes and alien materials
in the Bundle entry part (BDS01,
BDS02) sensors.
3. If no alien material exists, check
whether the sensor is polluted
I3310
[Entry In/Out]When trying to
discharge the media, the number
of retries exceeds the limit.
1. Check the inside of the Bundle(1).
2. Open the separation part of SCM and
Bundle and then remove residual
banknotes and the alien materials.
3. If no alien material exists, check
whether the sensor in the Bundle(1) is
polluted.
I3312
[Entry In/Out] Fault of receiving
media returned due to low-speed
moving path up.
1. Open the door at the Bundle side and
remove the residual media.
2. Check and remove the alien materials
in the Bundle low-speed wheel position
control (BDS14) sensor.
3. If no alien material exists, check
whether the sensor is polluted
4. Initialize the device.
I3315
[Entry In/Out]Fault of calling a
undefined command from Bundle.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3318
[Entry In/Out]Fault of performing a
undefined processing flow at
Bundle.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3319
[Entry In/Out]BDS06 Dark Timeout
when performing low-speed
moving path down.
1. Execute CCIM initialization.
2. Check whether the sensor (BDS06)
detecting the Bundle low-speed moving
path media is polluted when the same
error occurs after initialization.
I3325
[Entry In/Out]Detect Short Note
Entry(Under 110mm one note,
then BDS07,05 Dark /
BDS01,02,03,04 Light)
1.No actions taken