Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-159
Code
Problem Description
Troubleshooting
I5F19
[Deposit Reject]JError occurred by
the Return Transport
Path( FDS19)
1. Remove the residual media at the
Cassette2 entry (11).
2. Execute initialization.
I5F1A
[Deposit Reject]JError occurred by
the Return Transport
Path( CCS07)
1. Check residual media or alien
materials at the Cassette2(15) entry and
remove those.
I60C1
[Deposit Cancel] Receives
undefined USB CONTROL
command.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I60C2
[Deposit Cancel]A wrong size is
received during USB CONTROL
PIPE communication.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I60C3
[Deposit Cancel]The size of USB
bulk data is 0 or not the multiple of
64.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I60CF
[Deposit Cancel]Fault of
transmitting the same seq of SP.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I6301
[Deposit Cancel]Low-speed
control sensor fault.
1. Open the door at the Bundle side and
remove the residual media.
2. Check and remove the alien materials
in the Bundle low-speed wheel position
control (BDS14) sensor.
3. If no alien material exists, check
whether the sensor is polluted.
4. Initialize the device.
I6302
[Deposit Cancel]The delivering
roller with low-speed fails to
operate upward.
1. Check whether the Bundle low-speed
moving path (BDM02) is running.
2. Reboot the system when the same
error occurs.
3. Replace the motor and cables when
the same error occurs after checking the
device.
I6303
[Deposit Cancel]The delivering
roller with low-speed fails to
operate downward.
1. Check whether the Bundle low-speed
moving path (BDM02) is running.
2. Reboot the system when the same
error occurs.
3. Replace the motor and cables when
the same error occurs after checking the
device.
I6304
[Deposit Cancel]Shutter sensor
fault.
1. Check and remove the alien materials
in the Bundle Shutter Open (BDS11)
and Close(BDS12) sensors.
2. If no alien material exists, check
whether the sensor is polluted.
I6305
[Deposit Cancel]Shutter Open
fault.
1. Check the inside of the Bundle and
the Shutter.
2. Remove banknotes or the alien
materials in the Shutter.
3. Check whether the Shutter Open
successfully operates.