Error Code List Chapter4. Cash & Check In Module
4-68
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I3305
[Entry In/Out]Shutter Open fault.
1. Check the inside of the Bundle and
the Shutter.
2. Remove banknotes or the alien
materials in the Shutter.
3. Check whether the Shutter Open
successfully operates.
I3306
[Entry In/Out]Shutter Close fault.
1. Check the inside of the Bundle and
the Shutter.
2. Remove banknotes or the alien
materials in the Shutter.
3. Check whether the Shutter Close
successfully operates.
I3307
[Entry In/Out]Billpress sensor
fault.
1. Check and remove the alien materials
in the Bundle Bill Press part (BDS15,
BDS16) sensors.
2. If no alien material exists, check
whether the sensor is polluted
I3308
[Entry In/Out]Billpress move
position startup fault.
1. Check the inside of the Bundle(1).
2. Remove the alien materials of the
Billpress.
3. If no alien material exists in the
Billpress, check and remove the alien
materials in the Bundle Bill Press home
Position (BDS15) sensor.
4. If no alien material exists, check
whether the sensor is polluted.
I3309
[Entry In/Out]Billpress separation
position startup fault.
1. Check the inside of the Bundle(1).
2. Remove the alien materials of the
Billpress.
3. If the Billpress is up, check whether
the state is BDS18 Dark.
4. If it is not dark, move the P Roller and
check whether the state of BDS18 is
changed.
I330A
[Entry In/Out]Billpress residual
position startup fault.
1. Check the inside of the Bundle(1).
2. Remove the alien materials of the
Billpress.
3. If no alien material exists in the
Billpress, check and remove the alien
materials in the Bundle Bill Press
Up/Down (BDS16) sensor.
4. If no alien material exists, check
whether the sensor is polluted
I330B
[Entry In/Out] Billpress Reject
position startup fault.
1. Check the inside of the Bundle(1).
2. Remove the alien materials of the
Billpress.
3. If no alien material exists in the
Billpress, check and remove the alien
materials in the Bundle Bill Press part
(BDS15, BDS16) sensors.
4. If no alien material exists, check
whether the sensor is polluted