Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-34
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5202B00
Error occurred by the notes
remained on the Transport
Path (GS022) during Deposit
Count.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Remove the banknotes and the
foreign substance from the reject
cassette (19).
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202G00
Error occurred by the notes
remained on the Transport
Path (GS614) during Deposit
Count.
1. Open the upper unit.
2. Open the customer service module
(CSM)(3)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202H00
Error occurred by the notes
remained on the Transport
Path (GS618) during Deposit
Count.
1. Open the upper unit.
2. Open the customer service module
(CSM)(3)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202J00
Error occurred by the notes
remained on the Transport
Path (GS619) during Deposit
Count.
1. Open the upper unit.
2. Open the customer service module
(CSM)(3)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202K00
Error occurred by the notes
remained on the Transport
Path (GS703) during Deposit
Count.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5202M00
Error occurred by the notes
remained on the Transport
Path (GS031) during Deposit
Count.
1. Open the lower unit.
2. Rotate the knob of the Mid Transport
Path.
3. Remove notes and substance in the
Mid Transport Path (13).
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202N00
Error occurred by the notes
remained on the Transport
Path (GS032) during Deposit
Count.
1. Open the lower unit.
2. Rotate the knob of the mid Transport
Path.
3. Remove notes and substance in the
mid Transport Path (13).
4. Check whether the sensor is
contaminated or not if there are No
notes or substance