Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-1
Chapter2. Bill Recycling Machine
Code
Problem Description
Troubleshooting
5-SFF00
received undefined CMD
(Second ´-´
responses with real received
CMD).
1. Check bulk sending command is
defined
5102100
Error occurred by the notes
remained on the GS801 during
Deposit Ready.
1. Open the upper unit.
2. Open the customer service module
(CSM)
3. Open the BC(5)
4.Remove notes and substance in the
Front Transport Path(4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5102200
Error occurred by the notes
remained on GS002 during
Deposit Ready.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5102300
Error occurred by the notes
remained on GS003 during
Deposit Ready .
1. Open the upper unit.
2. Open the TE(Temporary Escrow)
(12).
3. Open the Rear Transport Path(6)
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5102400
Error occurred by the notes
remained on GS004 during
Deposit Ready .
1. Open the upper unit.
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9).
4. Remove notes and substance in the
Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5102500
Error occurred by the notes
remained on GS005 during
Deposit Ready .
1. Open the upper unit.
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance