Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-282
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
598R300
Message timeout error during
postprocessing to Customer
Change Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
598R900
BC message timeout error
during Customer Change.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
598S100
Receive abnormal MI from BC
during Customer Change.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
598S200
Receive abnormal BCC from
BC during Customer Change.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
598S400
Receive ETC. error from BC
during Customer Change.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
598S900
Receive retry error from BC
during Customer Change.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5991300
RJC GSA03 dark jam error
during Customer Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Open the reject cassette(21)
4. Remove substance in the reject
cassette(21)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5991500
RJC GSA05 dark jam error
during Customer Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Open the reject cassette(21)
4. Remove substance in the reject
cassette(21)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance.
599J100
RJC full detect error during
Customer Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
599P100
RJC motor error during
Customer Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Check the stage after open the door
and push the lever
5. Check the sensor.