Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-495
Code
Problem Description
Troubleshooting
5Q1GB00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
5Q1GC00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
5Q1GG00
Encoder Sensor(GS113) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction.
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS113 works fine if
there is nothing jammed.
5Q1GH00
Encoder Sensor(GS113) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS113 works fine if
there is nothing jammed.
5Q1J300
RC1 full check failure during
Retract CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Check the stage status after open the
recycle cassette(A)
5. Check contamination of sensor
GS112
5Q1R100
RC1 message timeout error
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q1R300
RC1 message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q1S100
Undefined return value of RC1
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
5Q1S200
Undefined command of RC1
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)