Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-514
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5QAAB00
Status of RC full before the
operation during Retract CSM
+ TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the GSx11 full detection
sensor of recycle cassettes(A~E)
4. Open the cassette door
5. Check the notes full in the cassette
5QAAC00
Status of RJC full before the
operation during Retract CSM
+ TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
5QAAD00
Status of UTC1 full before the
operation during Retract CSM
+ TE.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
5QAAE00
Status of UTC2 full before the
operation during Retract CSM
+ TE.
1. Open the upper unit
2. Open the forge note cassette(10
3. Check the forge note cassette(10) is
full
5QAAF00
Status of RC empty before the
operation during Retract CSM
+ TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the residual notes quantity in
the recycle cassettes(A~E)
5QAAG00
Removal status of RC to store
doubted notes before the
operation during Retract CSM
+ TE.
1. Check to load RC which receipts
doubted notes
2. Operate to initialize BRM(Recovery)
3. Excluding RC removed from doubted
cassette when you use a TE for the
test
5QAAH00
Unused status of RC to store
Retracted CSM notes before
the operation during Retract
CSM + TE.
1. Check that RC for retracting Notes is
equipped
2. Operate to initialize BRM(Recovery)
3. Excluding RC removed from
Retracted cassette when you use a TE
for the test
5QAAK00
Retracting cassette set UTC1
or UTC2 in unused UTC before
to operation during Retract
CSM + TE
1. Check the SP setting.
2. Restart over AP-SP
3. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5QAE100
Received operation command
without Initial Info Set during
Retract CSM + TE.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5QAE200
Status on not operation
receiption command during
Retract CSM + TE.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5QAE300
Received operation command
without System Info Read
during Retract CSM + TE.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization