Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-143
Code
Problem Description
Troubleshooting
546M600
Shutter Close error initializing
stopper during Deposit Cancel.
1. Open the upper unit
2. Check knob rotates softly in the
CSM(1)
3. Check inside of CSM
546M700
Shutter is forcibly opend during
Deposit Cancel.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
546P100
PP withdrawal(stack) position
movement error during Deposit
Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P200
PP deposit position movement
error during Deposit Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P300
PP separate position
movement error during Deposit
Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P400
PP lose return position
movement error during Deposit
Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P500
PP notes out error during
Deposit Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P600
PP notes alignment error
during Deposit Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P700
PP separate control(during
separating) error during
Deposit Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P800
PP stack control(during
stacking) error during Deposit
Cancel .
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
546P900
Error of reverting notes during
Deposit Cancel .
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the knob rotates softly in the
CSM(3)