Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-49
Code
Problem Description
Troubleshooting
5262300
Notes insert exceed error in
the CSM during Deposit Count.
1. Operate to initialize BRM(Recovery)
2. Check inserting notes into the CSM
are over 200 counts at one time
5262400
Undefined command error of
CSM during Deposit Count.
1. Operate to initialize BRM(Recovery)
5262500
The status of notes remain in
the CSM changed status of no
notes in the CSM during
Deposit Count.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
5262600
The status of no notes in the
CSM changed The status of
notes remain in the CSM
during Deposit Count.
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
526B100
Note Receive and position
error during Deposit Count.
Return Notes to customer(Semi OK
Code)
526B200
Separate Note does not exist
in the CSM during Deposit
Count.
Return Notes to customer(Semi OK
Code)
526B300
Separate Mis-pickuo during
Deposit Count.
Return Notes to customer(Semi OK
Code)
526B400
Separate disorder Jam(Front
Skew) during Deposit Count.
Return Notes to customer(Semi OK
Code)
526B500
Separate disorder Jam(Rear
skew) during Deposit Count.
Return Notes to customer(Semi OK
Code)
526B600
Separate disorder Jam(Max
length exceed) during Deposit
Count.
Return Notes to customer(Semi OK
Code)
526B700
Separate disorder Jam(Min
Length Exceed) during Deposit
Count.
Return Notes to customer(Semi OK
Code)
526B800
Separate disorder dark jam
during Deposit Count.
Return Notes to customer(Semi OK
Code)
526B900
Detected Separate Double
notes disorder (2 Notes) during
Deposit Count.
Return Notes to customer(Semi OK
Code)
526BB00
Separate disorder Jam(Max
length exceed -> GS801 Light
Jam) during Deposit Count.
1. Open the upper unit
2. Open the CSM(1) shutter
3. Check the notes and substance
inside of the CSM
526BC00
Separate disorder light jam
during Deposit Count.
Return Notes to customer(Semi OK
Code)
526BD00
Separate disorder jam(Hole.
ETC) during Deposit Count.
Return Notes to customer(Semi OK
Code)
526BE00
Separate note does exist in the
CSM Separation unit after
complete separation during
Deposit Count.
Return Notes to customer(Semi OK
Code)
526G100
BP stack position movement
error during Deposit Count.
1. Open the upper unit
2. Open the CSM(1) shutter
3. Check the notes and substance
inside of the CSM