Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-91
Code
Problem Description
Troubleshooting
I3D19
[Entry In/Out]Error occurred by the
notes disorder on the FDS19
1. Remove the residual media at the
Cassette2 entry (11).
2. Execute initialization.
I3D1A
[Entry In/Out]Error occurred by the
notes disorder on the CCS07
1. Check residual media or alien
materials at the Cassette2(15) entry and
remove those.
I3D33
[Entry In/Out]Continuous note gap
disorder error on the FDS01
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I3D34
[Entry In/Out]Continuous note gap
disorder error on the FDS02
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I3D35
[Entry In/Out]Continuous note gap
disorder error on the FDS03
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I3D36
[Entry In/Out]Continuous note gap
disorder error on the FDS04
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I3D37
[Entry In/Out]Continuous note gap
disorder error on the FDS05
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I3D38
[Entry In/Out]Continuous note gap
disorder error on the
FDS03,FDS04
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I3D39
[Entry In/Out]Continuous note gap
disorder error on the BCS01
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I3D3A
[Entry In/Out]Continuous note gap
disorder error on the BCS02
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I3D3B
[Entry In/Out]Continuous note gap
disorder error on the
BCS01,BCS02
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I3D3C
[Entry In/Out]Continuous note gap
disorder error on the FDS15
1. Open the BM4 moving path and then
remove the residual media and alien
materials.
I3D3D
[Entry In/Out]Continuous note gap
disorder error on the AAS06
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I3D3E
[Entry In/Out]Continuous note gap
disorder error on the AAS05
1. After opening the BM2(7) moving
path, open the Alignment(4) Guide2 to
remove media and alien materials.
2. Initialize the device.
4. If the same fault continuously occurs
after checking the device, replace the
Alignment(4) Module.