Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-305
Code
Problem Description
Troubleshooting
5A4GG00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Retract CSM.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5A4GH00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5A52500
Error occurred by the notes
remained on the GS505 during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A55500
Error occurred by the
Transport Path(GS505) during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A56500
Error occurred by the Return
Transport Path(GS505) during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A57500
Error occurred by the notes
disorder on the GS505 during
Retract CSM.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance