Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-372
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5D00J00
GS619 light jam error during
Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove Jam in the Rear Transport
Path(11).
5D00M00
GS031 light jam error during
Initialize.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove the Jam on the Mid
Transport Path(13).
5D00N00
GS032 light jam error during
Initialize.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove the Jam on the Mid
Transport Path(13).
5D00P00
GS033 light jam error during
Initialize.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove the Jam on the Mid
Transport Path(13).
5D00Q00
GS034 light jam error during
Initialize.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove the Jam on the Mid
Transport Path(13).
5D00W00
GS802 light jam error during
Initialize.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Open BC(5) and Rear Transport
Path(6)
4. Remove the Jam between BC(5) and
Rear Transport Path(6).
5D01100
GS801 dark jam error during
Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5D01200
GS002 dark jam error during
Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance