Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-396
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5D2G600
Exceeds retry count limit of
detecting RC2 stack
roller´s falling back and
avoiding during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Check the jam removal knob rotates
softly
5D2G700
Failure to move RC2 feed
roller to home position during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Check the jam removal knob rotates
softly
5D2G800
Failure to RC2 push pressure
movement during Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Check the upper side of the recycle
cassette
5D2GA00
RC2 solenoid echo disorder
error during Initialize .
1. Open the lower unit
2. Open the Mid Transport Path
3. Reload the recycle cassette (B) after
removing recycle cassette
4. Replace the cassette when same
error occurs
5D2GB00
Encoder Sensor(GS207) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Initialize .
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS207 works fine if
there is nothing jammed.
5D2GC00
Encoder Sensor(GS207) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Initialize .
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS207 works fine if
there is nothing jammed.
5D2GD00
Detect GS201, GS202 as
excessive notes during
Initialize
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove note.
5D2GE00
Detect GS208(separate
pressure) as excessive note at
FM homeposition movement
durting Initialize
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove note.