Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-33
Code
Problem Description
Troubleshooting
5202100
Error occurred by the notes
remained on the Transport
Path (GS801) during Deposit
Count .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202200
Error occurred by the notes
remained on the Transport
Path (GS002) during Deposit
Count .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202300
Error occurred by the notes
remained on the Transport
Path (GS003) during Deposit
Count.
1. Open the upper unit.
2. Open TE(12)
3. Open the Rear Transport Path(6)
4. Remove the notes and substance on
the Rear Transport Path(6)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202400
Error occurred by the notes
remained on the Transport
Path (GS004) during Deposit
Count.
1. Open the upper unit.
2. Open TE(12)
3. Open the Rear Transport Path(9)
4. Remove the notes and substance on
the Rear Transport Path(8)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202500
Error occurred by the notes
remained on the Transport
Path (GS005) during Deposit
Count.
1. Open the upper unit.
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202600
Error occurred by the notes
remained on the Transport
Path (GS006) during Deposit
Count.
1. Open the upper unit.
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove substance on the Rear
Transport Path(7)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5202A00
Error occurred by the notes
remained on the Transport
Path (GS021) during Deposit
Count.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance