Error Code List Chapter4. Cash & Check In Module
4-98
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I4109
[Deposit Count/Check] Fault of
exceeding the retries when the
Cassette1 Clamp failed to move to
the position (NCS08 Light).
1. Check the Cassette1 media guide
motor (NCM02) running and cable
connection.
2. If the same fault continuously occurs
after checking the device, replace the
Cassette1(14)
I410A
[Deposit Count/Check] Fault that
the home position is not detected
even when the Cassette1 Clamp
is running at the home position
(NCS08 Light).
1. Check the Cassette1 media guide
motor (NCM02) running and cable
connection.
2. If the same fault continuously occurs
after checking the device, replace the
Cassette1(14)
I410B
[Deposit Count/Check] Failure to
detect the bottom (NCS05) when
the Cassette1 Push Plate Stack
moves
1. Check the arrangement state of
banknotes in the Cassette.
2. Check the Stack position sensor
(NCS06) lever operation state.
3. If the Push Plate is not at the bottom,
check the alien materials at the
Cassette1 Bottom sensor(NCS05).
I4112
[Deposit Count/Check]The request
number is 0 when checking the
deposit in Cassette1.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4113
[Deposit Count/Check]The request
number exceeds 200 when
checking the deposit in Cassette1.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4114
[Deposit Count/Check]The request
number does not exist when
checking the deposit in Cassette1.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4203
[Deposit Count/Check]Fault of
calling a undefined command from
Cassette2.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4204
[Deposit Count/Check]Fault of
performing a undefined process
flow from Cassette2.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4205
[Deposit Count/Check]Cassette2
position of door open fault
1. Check the Cassette2(15) installation
state and door open state.
2. Check Cassette2 home position
(CCS01) sensor connection cable.
I4206
[Deposit Count/Check] Fault of
causing retry of moving the
Cassette2 Push Plate Bottom
position.
1. Check the jam when moving the push
plate left/right/vertically and manually.
2. Check the Cassette2 push plate
motor (CCM01) running and cable
connection.
I4207
[Deposit Count/Check]Jam at the
sensor (CCS07) detecting the
number of papers which enter into
the Cassette2.
1. Check residual media or alien
materials at the Cassette2(15) entry and
remove those.
I4208
[Deposit Count/Check] Fault of
causing retry of moving the
Cassette2 Push Plate top position.
1. Check the arrangement state of the
banknotes in the Cassette2(15).
2. Check the stack position (CCS06) and
the media entry detection (CCS09) prism
state.
3. If the same fault continuously occurs
after checking the device, replace the
Cassette2(15)