Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-126
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
541GC00
Encoder Sensor(GS107) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction duing
Deposit Cancel.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #1 and
open its door.(A)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS107 works fine if
there is nothing jammed.
541J300
Failure to RC1 full check
during Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Check the stage status after open the
recycle cassette(A)
5. Check contamination of sensor
GS112
541R100
RC1 message timeout error
during operation ready in the
Deposit Cancel.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
541R200
RC1 message timeout error
during transation operation in
the Deposit Cancel .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
541R300
RC1 message timeout error
during postprocessing of
Deposit Cancel Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
541S100
Undefined return value of RC1
during Deposit Cancel.
1. Operate to initialize BRM(Recovery)
541S200
Undefined command of RC1
during Deposit Cancel.
1. Operate to initialize BRM(Recovery)
5420500
GS205 light jam during Deposit
Cancel .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(15)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).
5421100
GS201 sensor jam during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove substance
6. Check whether the sensor is
contaminated or not if there are No
notes or substance.