This manual is suitable for:

Feature

Model

ETHERNET

CM550-52G/W/F

ETHERNET & GPS

CM550-55W/F

ETHERNET & ZIGBEE

CM550-56W/F

Xiamen Caimore Communication Technology Co.,Ltd

Add: 3F, 1st Building, 23# Wanghai Road, Xiamen

Tel

+86-592-3799895

Fax

0592-5975885 P

361009

Web

www.caimore.net

Email:[email protected]

版权所有

2003-2009

----

才茂通信 通畅天下

----

Summary of Contents for CM550-5 Series

Page 1: ...suitable for Feature Model ETHERNET CM550 52G W F ETHERNET GPS CM550 55W F ETHERNET ZIGBEE CM550 56W F Xiamen Caimore Communication Technology Co Ltd Add 3F 1st Building 23 Wanghai Road Xiamen Tel 86...

Page 2: ...unication technology co Ltd Trademark Caimore and other Caimore brands are possessed by Xiamen Caimore communication technology co Ltd Other brands or registered brands mentioned in this page are poss...

Page 3: ...upply 8 1 5 Indicator Light Instructions 8 2 Configuration 9 2 1 Basic 9 2 1 1 WAN 9 2 1 3 LAN 10 2 1 3 DDNS 10 2 1 4 Keep Alive 12 2 2 Advance 12 2 2 1 Filter 12 2 2 2 NAT DMZ 16 2 2 3 Route 18 2 3 V...

Page 4: ...aimore communication technology co Ltd Notice Please install the RTU without power Installation diagram of back Installation diagram of front 1 2 Unpacking To ensure the safe transportation RTU should...

Page 5: ...P 0057 Certification Certification 1 PCS 8 EZ 0002 Cutting ferrule SIM drawer type cutting ferrule 1 PCS 1 2 2 CM550 55X standard parts list NO Material NO Name Specifications and models Quantity Unit...

Page 6: ...sucker antenna dedicated for ZigBee 2 PCS 9 XL 0004 Data line Ethernet straight through line RJ45 RJ45 1M 1 PCS 1 3 Installation and Cable Connection 1 3 1 Installation of Antenna and SIM Card The ant...

Page 7: ...PWR pin the entire RTU will be cut off and the Power lights will go out When the pin is applied with 0V voltage or suspended the RTU is normally energized 4 D RX RS232 Debug Data receiver pin 5 D TX...

Page 8: ...ort 30V maximum current is 40mA maximum power is 125mW output frequency is 0 1KHz duty ratio adjustable 26 DO2 27 DO3 28 DO4 29 K1 Relay Output Drive capability 5A 30VDC 5A 250VAC 30 K1 31 K2 32 K2 33...

Page 9: ...Xiamen Caimore Communication Technology Co Ltd 6 Blue D RX Black GND 3 RS485 Color of Wire Definition of signal Red RS485 anode A Black RS485 cathode B Connection 2 DI Only support wet...

Page 10: ...Xiamen Caimore Communication Technology Co Ltd 7 3 Optocoupler Output Digital Output 4 Relay Output 5 Analog Input...

Page 11: ...hey must guarantee the stability of power supply the ripple wave is less than 300mV and ensure the transient voltages is less than 30V and please ensure the power is more than 4W Recommend the standar...

Page 12: ...nder normal condition they are can be left as default But if there is using the VPDN please type they according to the info provided by operator Notice If there is PIN or other parameters need to be t...

Page 13: ...LAN is 192 168 1 0 24 and its default LAN IP is 192 168 1 2 You can leave it as default Notice If you want to change LAN segment please make sure that RTU s LAN1 IP is between Start IP and End IP 2 1...

Page 14: ...88IP supply DNS server address check http www 88ip cn Info list asp Unid 89 Interval How long to update one time Username Username to log in 88ip server Password password to log in 88ip server Oray U...

Page 15: ...can be left in default value Notice a If this function has been closed then the RTU will not detect the network state so RTU will not restart and re dial even if it s offline b The destination IP shou...

Page 16: ...ckets can go through Receiving matching following rule data packets only receive data packets comply to following rule others are discarded IP Filter To realize IP address filtering rules appointing r...

Page 17: ...ay allows all data to go through but not allowed data packet to go through 3 Input parameters in IP rule This example parameter is Name enableipfilter01 LAN IP 192 168 1 23 WAN IP 121 204 201 13 Proto...

Page 18: ...cture 3 Input parameters in IP rule This example parameter Name enableipfilter02 LAN IP 192 168 1 23 WAN IP 121 204 201 13 Protocol all Direction IN OUT Interface PPP0 Read picture 4 10 3 then click S...

Page 19: ...MAC address filtering 2 Running rule select discard packet matching following fule 3 Input 00 00 23 34 45 56 in MAC So gateway will discard all data packet of MAC address 00 00 23 34 45 56 meanwhile...

Page 20: ...External Port WAN port Internal IPAddress The private IP address you want to map to external Internal Port The port of internal host you want to map to external DMZ In order to achieve the both way co...

Page 21: ...segment Mask Subnet mask of destination IP If destination is a host please set mask to 255 255 255 255 Gateway Next hop IP of static route If there is no need to add a gateway please set it to 0 0 0 0...

Page 22: ...d to create tunnel if it is blank it means to use WAN IP address MTU the max data packets which can go through tunnel 2 3 2 PPTP PPTP is a protocol in layer 2 it transfers data by encapsulating PPP da...

Page 23: ...gh the tunnel If not then these devices only can access server via Internet Specify Local IP Specify Peer IP If PPTP server allows it router can specify a local tunnel IP address Tunnel Check Interval...

Page 24: ...nel usually used in the connection between two routers Passthrough it allows IPSec protocol to pass through Local Endpoint Type Network to Network used in the communication between devices connected t...

Page 25: ...15 Group16 Group17 and Group18 SA Lifetime Phase negotiation time Key When Authentication is Pre shared Key it s the shared key Password When Authentication is Certificates it s the password of certif...

Page 26: ...text the security level of it is low Chap MS Chap MS Chap V2 Any it will take one of four approaches to verify MPPE Way to encrypt NoMppe No encryption Mppe 40 128 Mppe StateFul Add Default Route If...

Page 27: ...arated by 2 4 RTU 2 4 1 Server Server Parameters Configure Server IP address Server IP that wants to connect and fill the IP address according to the format as picture Server s domain name is acceptab...

Page 28: ...r the option that is to be set After finishing the edit click to save them Click to save after setting the server parameters which will take effect after rebooting the device RTU Identify RTU ID the i...

Page 29: ...edit click to save them Click to save after setting the server parameters which will take effect after rebooting the device 2 4 3 PWM Relay PWM Output Frequency set the frequency of PWM output square...

Page 30: ...t box inputting the figure or the option that is to be set After finishing the edit click to save them Click to save after setting the server parameters which will take effect after rebooting the devi...

Page 31: ...t Alarm trigger Conditions Low level High level Mobile phone number for alarm The alarm information will be sent to the mobile phone by SMS message Alarm contents The alarm contents will be sent to th...

Page 32: ...uration Method Click the corresponding Edit box directly then enter the value or select the item to set when editing is complete please click to save Click to save after finishing the setting of serve...

Page 33: ...rent of top range and the corresponding voltage current of low range Corresponding voltage current of top range upper limit of voltage or current True value of top range the corresponding true data of...

Page 34: ...it value of alarm or the maximum value of limitation Number of alarm when alarm generates the phone number that alarm is sent to Alarm content when alarm generates the alarm content that alarm is sent...

Page 35: ...estart Active reporting configuration Allow the active report or not it means whether allow to actively report the acquisition data of analog input Active report intervals after allowing the above par...

Page 36: ...parate them with comma If you want to make all phone allowed to query it please type all in this box Query content of analog input the message used to query analog input status Support letters Numbers...

Page 37: ...query it please type all in this box Query relay status SMS content the message used to query relay status Support letters Numbers underscores Spaces SMS Query Digital Input Status Allowed query phone...

Page 38: ...rate them with comma If you want to make all phone allowed to query it please type all in this box Set digital output high level SMS content the content of SMS to control digital to output high level...

Page 39: ...re them according to actual situation Mode There is only one mode can be chosen TCP Protocol Set which working protocol to use The default is the DTU protocol If the customer needs CUSTOM registration...

Page 40: ...of Keepalive The interval between periodic sending of online monitoring data to maintain the link Unit seconds The default value is 60 seconds It is suggested that the heartbeat time should not be set...

Page 41: ...Co Ltd 38 2 5 2 DTU for RS485 Please refer to 2 5 1 DTU for RS232 Technical Support If there is any doubt please access our official website www caimore net or contact technical support staff and who...