Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-134
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
543S100
Undefined return value of RC3
during Deposit Cancel.
1. Operate to initialize BRM(Recovery)
543S200
Undefined command of RC3
during Deposit Cancel.
1. Operate to initialize BRM(Recovery)
5440500
GS405 Light Jam during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(17)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).
5441100
GS401 sensor jam during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove substance
6. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5441200
GS402 sensor jam during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove substance
6. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5441500
GS405 sensor jam during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove substance
6. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5442100
Error occurred by the notes
remained on the GS401 during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Put down the Stage after open the
recycle cassette door (D)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance