Code
Problem Description
Troubleshooting
5B4J300
RC4 full check failure during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Check the stage status after open the
recycle cassette(D)
5. Check contamination status of the
GS412 sensor.
5B4R100
RC4 message timeout error
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B4R200
RC4 message timeout error
Transaction.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B4R300
RC4 message timeout error in
process of the error treatment
during Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B4S100
Undefined return value of RC4
during Retract TE.
1. Operate to initialize BRM(Recovery)
5B4S200
Undefined command of RC4
during Retract TE.
1. Operate to initialize BRM(Recovery)
5B50500
GS505 light jam error during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(18)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).
5B51100
GS501 sensor jam during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5B51200
GS502 sensor jam during
Retract TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Put down the Stage after open the
recycle cassette door (E)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance