Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-131
Code
Problem Description
Troubleshooting
5431500
GS305 sensor jam during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove substance
6. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5432100
Error occurred by the notes
remained on the GS301 during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5432200
Error occurred by the notes
remained on the GS302 during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5432500
Error occurred by the notes
remained on the GS305 during
Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5435500
Error occurred by the
Transport Path on the GS305
during Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance