Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-239
Code
Problem Description
Troubleshooting
578R300
BC message timeout error
during postprocessing of
Withdrawal Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
578R900
BC message timeout error
during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
578RJ00
BC message timeout error
during Stop Ready Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
578S100
Receive abnormal MI from BC
during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
578S200
Receive abnormal BCC from
BC during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
578S400
Receive ETC. error from BC
during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
578S900
Receive retry error from BC
during Withdrawal.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5791300
RJC GSA03 dark jam error
during Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Open the reject cassette(21)
4. Remove notes and substance in the
reject cassette(21)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5791500
RJC GSA05 dark jam error
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Open the reject cassette(21)
4. Remove notes and substance in the
reject cassette(21)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
579J100
RJC full detection error during
Withdrawal.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.