Error Code List Chapter4. Cash & Check In Module
4-212
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I810A
[Deposit End] Fault that the home
position is not detected even when
the Cassette1 Clamp is running at
the home position (NCS08 Light).
1. Check the Cassette1 media guide
motor (NCM02) running and cable
connection.
2. If the same fault continuously occurs
after checking the device, replace the
Cassette1(14)
I810B
[Deposit End] Failure to detect the
bottom (NCS05) when the
Cassette1 Push Plate Stack
moves
1. Check the arrangement state of
banknotes in the Cassette.
2. Check the Stack position sensor
(NCS06) lever operation state.
3. If the Push Plate is not at the bottom,
check the alien materials at the
Cassette1 Bottom sensor(NCS05).
I8203
[Deposit End]Fault of calling a
undefined command from
Cassette2.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I8204
[Deposit End]Fault of performing a
undefined process flow from
Cassette2.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I8205
[Deposit End]Cassette2 position of
door open fault
1. Check the Cassette2(15) installation
state and door open state.
2. Check Cassette2 home position
(CCS01) sensor connection cable.
I8206
[Deposit End] Fault of causing
retry of moving the Cassette2
Push Plate Bottom position.
1. Check the jam when moving the push
plate left/right/vertically and manually.
2. Check the Cassette2 push plate
motor (CCM01) running and cable
connection.
I8207
[Deposit End]Jam at the sensor
(CCS07) detecting the number of
papers which enter into the
Cassette2.
1. Check residual media or alien
materials at the Cassette2(15) entry and
remove those.
I8208
[Deposit End] Fault of causing
retry of moving the Cassette2
Push Plate Top position.
1. Check the arrangement state of the
banknotes in the Cassette2(15).
2. Check the stack position (CCS06) and
the media entry detection (CCS09) prism
state.
3. If the same fault continuously occurs
after checking the device, replace the
Cassette2(15)
I8209
[Deposit End] Fault of exceeding
the retries when the Cassette2
Clamp failed to move to the
position (CCS08 Light).
1. Check the Cassette2 media guide
motor (CCM02) running and cable
connection.
2. If the same fault continuously occurs
after checking the device, replace the
Cassette2(15).
I820A
[Deposit End] Fault that the home
position is not detected even when
the Cassette2 Clamp is running at
the home position (CCS08 Light).
1. Check the Cassette2 media guide
motor (CCM02) running and cable
connection.
2. If the same fault continuously occurs
after checking the device, replace the
Cassette2(15)