Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-501
Code
Problem Description
Troubleshooting
5Q4GB00
Encoder Sensor(GS407) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS407 works fine if
there is nothing jammed.
5Q4GC00
Encoder Sensor(GS407) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS407 works fine if
there is nothing jammed.
5Q4GG00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction.
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5Q4GH00
Encoder Sensor(GS413) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Retract CSM + TE.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #4 and
open its door.(D)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS413 works fine if
there is nothing jammed.
5Q4J300
RC4 full check failure during
Retract CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (D)
4. Check the stage status after open the
recycle cassette(D)
5. Check contamination status of the
GS412 sensor.
5Q4R100
RC4 message timeout error
Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q4R300
RC4 message timeout error in
process of the error treatment
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q4S100
Undefined return value of RC4
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
5Q4S200
Undefined command of RC4
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)