Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-510
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5Q8R200
BC message timeout error
during transation operation in
the Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q8R300
BC message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q8R900
BC message timeout error
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q8S100
Receive abnormal MI from BC
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q8S200
Receive abnormal BCC from
BC during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q8S400
Receive ETC. error from BC
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q8S900
Receive retry error from BC
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q9J100
RJC full detect error during
Retract CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove reject cassette(21)
4. Remove notes after checking notes
full in the cassette
5. Check whether the sensor is
contaminated or not if a cassette is
empty.
5Q9R100
RJC message timeout error
during operation ready in the
Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q9R300
RJC message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5QA2100
Status of remaining notes on
the return Path(GS801) before
the operation during Retract
CSM + TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance