Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-51
Code
Problem Description
Troubleshooting
I2871
[Shutter]Deposit reject command
is received when the residual
media are not detected at the
Reject part.
1. Remove the residual media in the
device.
2. Execute initialization.
I2872
[Shutter]Detects residual media at
the Reject part
1. Remove the residual media in the
device.
2. Execute initialization.
I2879
[Shutter] A fault occurs while
preparing for BC part.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I287A
[Shutter]BC response timeout.
1. Check the cable connecting between
Main and BC (Connector CN37).
I287B
[Shutter] The number of notes
which have passed BC is not
consistent with that of Escrow and
Reject.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I287C
[Shutter]BC operation is not
completed.
1. Remove the residual media in the
device.
2. Check the BC Cover(3) Lock state.
3. Execute initialization.
I28E0
[Shutter]Anomaly of check
information
1. Remove the residual media in the
device.
2. Execute initialization.
I28F1
[Shutter]Internal Error while the
main task is operating.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I28FF
[Shutter] Failed to move to 3-Way
1 or 3-Way 2 Gate position
1. Open the BM2(7) and BM2(12) and
remove the residual media at the moving
path (7, 8, 9, 10).
2. Execute initialization.
I2B01
[Shutter] Jam at the BC entry
sensor (BCS01,BCS02).
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I2B02
[Shutter]Jam at the Align detection
sensor (AAS02).
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I2B03
[Shutter]Align detection sensor
(AAS03) jam.
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I2B04
[Shutter]Recog detection sensor
(RCS01) jam.
1. Remove the internal media and alien
materials in the Recognition(5).
2. Initialize the device.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.