Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-493
Code
Problem Description
Troubleshooting
5Q0G200
Failure to 3 Way Gate 120
degree mode conversion
during Retract CSM + TE.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path
5Q0K100
Erro of failure to duplicate
serial number during Retract
CSM + TE
1. Check the duplicate note and remove
the note.
2. Operate to initialize BRM(Recovery)
5Q0K200
Status of UTC1 and UTC2 full
during Retract CSM + TE.
1. Open the upper unit
2. Open the cassette not received(9)
3. Check the cassette not received(9) is
full
5Q0NA00
Checksum error when
separate TE notes from TE
during Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
5Q0Q100
UTC removal error during
Retract CSM + TE.
1. Open the upper unit
2. Check removal of the cassette not
received(9)
5Q0Q200
TE open error during Retract
CSM + TE.
1. Open the upper Unit
2. Check open/close of TE(12)
5Q0Q300
BMU inter lock error during
Retract CSM + TE.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
5Q0Q400
BMU removal error during
Retract CSM + TE.
1. Check Load/Removal of the upper
unit
5Q0Q500
Safe door open error during
Retract CSM + TE.
1. Check the safe door open
5Q0Q600
CSM open error during Retract
CSM + TE.
1. Open the upper unit
2. Check to open/close CSM
3. Check the sensors GS011
5Q0Q700
RJC removal error during
Retract CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
5Q0Q800
BMD inter lock error during
Retract CSM + TE.
1. Check the lower Unit load/removal
2. Replace a cherry switch when error
occures
5Q0Q900
BMD removal error during
Retract CSM + TE.
1. Check the lower Unit load/removal
5Q0QA00
BC open error during Retract
CSM + TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Check the lock lever in the BC
5Q0R100
BM message timeout error
during operation ready in the
Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q0R300
BM message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization