Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-172
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
563GB00
Encoder Sensor(GS307) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS307 works fine if
there is nothing jammed.
563GC00
Encoder Sensor(GS307) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #3 and
open its door.(C)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS307 works fine if
there is nothing jammed.
563GD00
Detect GS301, GS302 as
excessive notes during
Withdrawal Ready
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove note.
563GE00
Detect GS308(separate
pressure) as excessive note at
FM homeposition movement
durting Withdrawal Ready
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Put down the Stage after open the
recycle cassette door (C)
5. Remove note.
563J200
RC3 empty during Withdrawal
Ready.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (C)
4. Check the notes remain after Open
the recycle cassette door(C)
5. Fill up the Notes if there are no notes
6. Check whether the sensor is
contaminated if there are Notes.
563R100
RC3 message timeout error
during operation ready in the
Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
563R200
RC3 message timeout error
during transation operation in
the Withdrawal Ready .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
563R300
RC3 message timeout error
during postprocessing of
Withdrawal Ready Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
563RJ00
RC3 message timeout error
during Stop Ready in the
Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
563S100
Undefined return value of RC3
during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)
563S200
Undefined command of RC3
during Withdrawal Ready.
1. Operate to initialize BRM(Recovery)