Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-414
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5D6P800
PP stack control(during
stacking) error during Initialize.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5D6P900
Error of reverting notes during
Initialize.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the knob rotates softly in the
CSM(3)
5D6PA00
PP preparation stop error
during Initialize.
1. Operate to initialize BRM(Recovery)
5D6R100
CSM message timeout error
during operation ready in the
Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D6R200
CSM message timeout error
during transaction operation in
the Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D6R300
CSM message timeout error
during postprocessing to
Initialize Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D71300
GS703 dark jam during
Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5D72100
Error occurred by the notes
remained on the GS701 during
Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5D72200
Error occurred by the notes
remained on the GS702 during
Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5D72300
Error occurred by the notes
remained on the GS703 during
Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5D72800
Error occurred by the notes
remained on the GS709 during
Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)