Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-232
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
576G400
Error of BP separate position
movement during Withdrawal .
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
576G500
BP separate control error
during Withdrawal .
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
576G800
Failure to revert notes during
Withdrawal .
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the GS660 sensor status
576GA00
Failure to revert notes during
Withdrawal (Separate moter
disorder).
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
576GB00
Failure to move
withdrawal(stack) position of
stack roller during Withdrawal
Stack roller (GM605 disorder).
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
576GC00
Failure to move deposit(stack)
position of stack roller during
Withdrawal Stack roller
(GM605 disorder).
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
576GD00
Failure to Lift-up during
Withdrawal.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
576GE00
Failure to Lift-down during
Withdrawal.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
576GF00
Failure to move gate roller to
home position during
Withdrawal.
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(2)
576M100
Stopper down error during
Withdrawal.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
576M300
Shutter close error during
Withdrawal.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
576M400
Stopper down error during
Withdrawal.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
576M500
Stopper up error during
Withdrawal.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM