Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-248
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5862500
The status of notes remain in
the CSM changed status of no
notes in the CSM during
Withdrawal .
1. Open the upper unit
2. Open CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
5862600
The status of no notes in the
CSM changed The status of
notes remain in the CSM
during Withdrawal .
1. Open the upper unit
2. Open the CSM shutter(1)
3. Check the notes and substance
inside of CSM
4. Check the sensors related with error
586G100
BP stack position movement
error during Notes Out.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
586G200
BP notes out error during
Notes Out.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
586G300
BP separate position
movement error during Notes
Out.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
586G400
BP separate control error
during Notes Out.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
586G500
BP notes out position error
during Notes Out.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
586M100
Stopper Init error during Notes
Out.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
586M500
Stopper up error during Notes
Out.
1. Open the upper unit
2. Check shutter knob rotates softly in
the CSM(1)
3. Check inside of CSM
586M600
Shutter Close error initializing
stopper during Notes Out.
1. Open the upper unit
2. Check knob rotates softly in the
CSM(1)
3. Check inside of CSM
586P100
PP withdrawal(stack) position
movement error during Notes
Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
586P200
PP deposit position movement
error during Notes Out.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)