Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-439
Code
Problem Description
Troubleshooting
5J8HG07
Error of BCU undefined
command reception during
Stop Ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred after initialization
5J8HG08
Error of available support
country numbers set up during
receiving BCU data write
command in the Stop Ready .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
5J8HG09
Error of country-code set up
during receiving BCU data
write command in the Stop
Ready .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
5J8HG10
Error of no recognition DB for
the country during receiving
BCU data write command in
the Stop Ready .
1. Check the country
2. Download DB again after delecting all
recognition DB
3. Operate to initialize BRM(Recovery)
4. Reboot the system when same error
occurred after initialization
5J8HG11
Error of no country code set up
during receiving BCU ready
command in the Stop Ready .
1. Check the country
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initialization
5J8HG12
BC spec differs from data write
command paramter in the Stop
Ready.
1. Check the BCU specifications.
2. Operate to initialize BRM(Recovery)
3. Reboot the system when same error
occurred after initializatio
5J8HG20
Error to initialize CIS during
receiving BCU ready command
in the Stop Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5J8HG21
Error of power on during
receiving BCU ready command
in the Stop Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5J8HG22
Error of DD sensor initialization
during receiving BCU ready
command in the Stop Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance
5J8HG23
Error of set up for DD sensor
DAC during receiving BCU
ready command in the Stop
Ready .
1. Operate to initialize BRM(Recovery)
2. Check whether the sensor is
contaminated or not if same error
occures after Initialize
3. Reboot the system when same error
occures even though there is no
substance