Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-412
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5D6G300
BP Separate position error
during Initialize.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5D6G400
BP separate control error
during Initialize.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5D6G500
BP notes out position error
during Initialize.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
5D6G600
Failure to move pickup-roller to
home position during Initialize.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the GS660 sensor status
5D6G800
Failure to revert
notes(Separate motor
disorder) during Initialize.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the GS660 sensor status
5D6GA00
Failure to move
withdrawal(stack) position of
stack roller(GM605 disorder)
during Initialize.
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
5D6GB00
Failure to move depositposition
of stack roller Stack roller
(GM605 disorder) during
Initialize.
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
5D6GC00
Failure to control stack
roller(GM605 disorder) during
Initialize.
1. Open the upper unit
2. Check the knob rotates softly in the
CSM(3)
5D6GD00
Failure to Lift-up during
Initialize.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
5D6GE00
Failure to Lift-down during
Initialize.
1. Open the upper unit.
2. Open the customer service module
(CSM) shutter(1)
3.Check the notes and substance inside
of the CSM
5D6GF00
Failure to move gate roller to
home position during Initialize.
1. Open the upper unit.
2. Check the knob rotates softly in the
CSM(2)
5D6H200
FP deposit position movement
failure(GS652 dark) during
Initialize.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check PP rotates softly using knob of
the CSM(1)