Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-65
Code
Problem Description
Troubleshooting
I2F13
[Shutter]Error occurred by the
Return Transport Path( FDS18)
1. Open the BM2(7) and remove the
residual media at the moving path (6)
and Cassette1(14) entry.
2. Execute initialization.
I2F14
[Shutter]Error occurred by the
Return Transport Path( NCS07)
1. Check residual media or alien
materials at the Cassette1(14) entry and
remove those.
I2F15
[Shutter]Error occurred by the
Return Transport Path( RJS08)
1. Remove the residual media in the
device.
2. Execute initialization.
I2F16
[Shutter]Error occurred by the
Return Transport Path( PRS01)
1. Open the third moving path (8) and
then remove the residual media and
alien materials.
2. Check the 3Way-Gate2 operation
state (FDM07)
I2F17
[Shutter]Error occurred by the
Return Transport Path( FDS16)
1. Open the BM3 moving path and then
remove the residual media and alien
materials.
2. Check the arrangement state of
banknotes in the RT box.
I2F18
[Shutter]Error occurred by the
Return Transport Path( RTS02)
1. Open the BM2(7) and remove the
residual media at the moving path (6, 7,
8, 9).
2. Remove the notes in the Retract Box.
3. Execute initialization.
I2F19
[Shutter]Error occurred by the
Return Transport Path( FDS19)
1. Remove the residual media at the
Cassette2 entry (11).
2. Execute initialization.
I2F1A
[Shutter]Error occurred by the
Return Transport Path( CCS07)
1. Check residual media or alien
materials at the Cassette2(15) entry and
remove those.
I30C1
[Entry In/Out] Receives undefined
USB CONTROL command.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I30C2
[Entry In/Out]A wrong size is
received during USB CONTROL
PIPE communication.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I30C3
[Entry In/Out]The size of USB bulk
data is 0 or not the multiple of 64.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I30CF
[Entry In/Out]Fault of transmitting
the same seq of SP.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3103
[Entry In/Out]Fault of calling a
undefined command from
Cassette1.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3104
[Entry In/Out]Fault of performing a
undefined processing flow at
Cassette1.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I3105
[Entry In/Out]Cassette1 position or
door open fault
1. Check the Cassette1(14) installation
state and door open state.
2. Check Cassette1 home position
(NCS01) sensor connection cable.