Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-288
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5A00100
GS801 light jam error during
Retract CSM.
1. Open the upper unit.
2. Check the Front Transport Path(4)
knob rotates softly
3.Check remained Notes and substance
in the upper Transport Path
4. Open the customer service module
(CSM)
5. Open the BC(5)
6.Remove notes and substance in the
Front Transport Path(4)
7. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A00300
GS003 light jam error during
Retract CSM.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Open BC(5) and Rear Transport
Path(6)
4. Remove the Jam between BC(5) and
Rear Transport Path(6).
5A00500
GS005 light jam error during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove the Jam between Rear
Transport Path(11) and Rear Transport
Path(6).
5A00K00
GS703 light jam error during
Retract CSM.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the Jam between TE(12)
and Rear Transport Path(11).
5A00W00
GS802 light jam error during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the Jam between BC(5) and
Front Transport Path(4).
5A01100
GS801 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5A01200
GS002 dark jam error during
Retract CSM.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove the notes and the substance
from the Front Transport Path (4)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance