Code
Problem Description
Troubleshooting
5PAE200
Not be performed Received
Command during CST notes
count Detete.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5PAE300
Received operation command
without System Info Read
during CST notes count
Detete.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5PAE400
CST notes count Detete
transaction was executed
without Initializing after power
on.
1. Restart over AP-SP
2. Do transation operation follow by set
up read system Info for TM Test-> Initail
Info Set -> Initialization
5PAE600
Error to received CST notes
count Detete. during TE Button
Operating.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5PAEE00
RBU RS485 Connecttion
Sequence error during CST
notes count Detete.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5PAEF00
RBU RS485 connection line
error during CST notes count
Detete.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5PAH500
Error to
NVRAM(128denominations)
Read/ Write during CST notes
count Detete.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization.
5PBH100
RC1 EEPROM read error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBH200
RC2 EEPROM read error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBH300
RC3 EEPROM read error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBH400
RC4 EEPROM read error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBH500
RC5 EEPROM read error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBH600
RC1 EEPROM write error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures