Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-109
Code
Problem Description
Troubleshooting
I452E
[Deposit Count/Check]The
residual media before the Escrow
entry or Drum is detected (ESS04,
ESS03) while winding the media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I452F
[Deposit Count/Check]The
residual media before the Escrow
entry or Drum is detected (ESS04,
ESS03) while winding the media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I4530
[Deposit Count/Check]The
residual media before the Escrow
entry or Drum is detected (ESS04,
ESS03) while discharging the
media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I4531
[Deposit Count/Check]The
residual media before the Escrow
entry or Drum is detected (ESS04,
ESS03) while discharging the
media.
1. Open the Escrow Part(12).
2. Remove the media at the Escrow
Drum residual check (ESS03) and
output check (ESS04) sensor part and
the pollution.
3. Execute CCIM initialization.
I4580
[Deposit Count/Check]Receives a
command which says to unwind
the roll of the Escrow until
exceeding the number of winding
media.
1. Check Sensor (Escrow entry (FDS15)
and output check (EES04) sensor)
2. Execute initialization.
I45F1
[Deposit Count/Check]Escrow
task force shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4602
[Deposit Count/Check]Batch
moving stage down fail.
1. Check whether the reject batch return
stage down detection (RJS07) sensor is
normally running.
2. Check whether the multiple return
clamp motor (RJM01) is running.
I4603
[Deposit Count/Check]Batch
moving stage up fail.
1. Check whether the reject batch return
stage up detection (RJS06) sensor is
normally running.
2. Check whether the multiple return
clamp motor (RJM01) is running.
I4604
[Deposit Count/Check]Batch
moving stage sensor fault.
1. Check whether the reject batch return
stage down detection (RJS07) sensor is
normally running.
2. Check whether the multiple return
clamp motor (RJM01) is running.